Yongda Yongda

Smart Thermostats & Actuators in the Ireland Market

Premium Hydronic & HVAC Control Systems Engineered for Energy Efficiency, Part L Compliance, and Sustainable Retrofits.

Send Inquiry Now

The Irish Retrofit & Electrification Revolution

As Ireland aggressively pursues its Climate Action Plan target to retrofit over 500,000 homes to B2 BER standards and install 400,000 heat pumps by 2030, the demand for high-efficiency zone control systems has soared.

Hydronic heating systems, powered by modern air-to-water heat pumps, rely fundamentally on the precise modulation of water temperatures. Smart thermostats, multi-zone wiring centers (hubs), and high-performance electrothermal actuators are the vital links ensuring that energy distribution matches occupancy needs. By converting static heating circuits into dynamic, intelligent networks, our systems directly lower heat loss, maximize heat pump Coefficient of Performance (COP), and guarantee strict compliance with Irish Building Regulations Part L.

Smart Thermostat Actuator Systems Deployment in Irish Buildings

Featured Intelligent Hubs & Room Controllers

Optimized for Irish zoning requirements, multi-floor plans, and integration with modern air-to-water heat pump protocols.

Bulk Sourcing Consultation & Pricing

Industrial & Commercial HVAC Operations in Ireland

From pharmaceutical cleanrooms to Dublin’s hyper-scale data centers: custom thermal actuator solutions built for operational resilience.

Ireland represents one of Europe's most unique energy landscapes. With Dublin hosting the continent's densest concentration of technology hubs, district heating networks, and commercial office spaces, strict thermal control is non-negotiable. Building services engineers require ruggedized valves and fast-acting actuators to handle the constant, low-delta-T flows typical in modern commercial buildings.

Furthermore, industrial plants, especially in Ireland’s highly active pharmaceutical and biotechnology sectors, mandate HVAC systems that deliver extremely stable environmental parameters. In these fields, deviation of even 0.5°C can compromise multi-million euro batches of product. The deployment of high-torque, waterproof electrothermal actuators integrated with central Building Management Systems (BMS) ensures consistent control parameters and helps maintain system stability under varying load conditions.

Our manufacturing processes address these strict environments. By fabricating components from robust, dezincification-resistant (DZR) lead-free brass and optimizing thermal expansion elements within our wax motors, our actuators deliver reliable operation over hundreds of thousands of cycles. This reliability directly matches the expectations of European engineering firms looking to lower lifetime maintenance costs and prevent costly system downtime.

Ireland HVAC Regulatory Milestones

  • Part L Compliance: New residential builds must include heating zone controls for systems exceeding 45m².
  • BER Enhancements: Upgrading manual radiator valves to electronic TRVs with smart actuators improves Building Energy Ratings (BER).
  • SEAI Grants: Supports the installation of smart heating control systems to help homeowners cut carbon footprints.
  • Net-Zero 2050: Mandatory shifts toward carbon-neutral heating systems across commercial retrofits.

Industrial Scale, Manufacturing Expertise & Global Footprint

Delivering HVAC valves, fittings, and thermal actuators to global markets since 1996.

Yuhuan Yongda Fluid Control Manufacturing Center

Yuhuan Yongda Fluid Control Co., Ltd.

Established in 1996 in Yuhuan, Zhejiang—known globally as the "China Valve Capital"—we have spent nearly three decades refining the engineering and production of premium plumbing, hydronic, and HVAC components. Spanning a factory footprint of 45,000 square meters (with a total usable floor area of 80,000 square meters), our plant hosts over 600 sets of advanced manufacturing and testing equipment.

Under our dedicated brand, Cokaren, we pledge a simple promise: "Keep flowing, keep warming". By focusing on refined designs, lead-free environmental compliance, and precise manufacturing tolerances, Cokaren works as a reliable OEM/ODM partner for European and North American distributors, mechanical wholesalers, and HVAC system integrators.

Our products span three core segments: environmental brass valves, pipe fittings, and smart HVAC control components (specifically underfloor heating manifolds, thermal actuators, and room controllers). With direct exports to over 20 countries, our systems manage thermal comfort in residential and commercial buildings worldwide.

1996
Founded Year
80,000+ m²
Usable Factory Area
600+ Sets
Advanced Test Machinery
20+ Countries
Export Destination Network

Holistic Energy Distribution Control System

From water inlet to smart room zoning—how our valves, manifolds, and actuators function together.

Yongda Valves Energy Distribution System Blueprint
Y9021 Water Filter

Y9021 Domestic Water Filter

Protects system components by filtering out up to 98% of particulates and debris within the pipeline.

Boiler Angel Valve Y5001/Y5002

Boiler Angle Valve Y5001/Y5002

Spherical spool configuration built for regulating inflow and outflow lines in boiler systems.

Y9070 Venting Valve

Y9070 Automatic Air Vent

Safely exhausts trapped air pockets in heat pump circuits to maintain energy transfer rates.

Y5020 Mixing Shunt

Y5020 Mixing & Shunting Valve

Blends high-temp supply with return flows to safeguard sensitive underfloor heating loops.

Y9031 Smart Thermostat

Y9031 Smart Room Thermostat

Coordinates multiple zoning devices to maintain target comfort levels across building sectors.

Y1001 Manifold

Y1001 Underfloor Heating Manifold

Precision flow-balancing headers engineered to distribute low-temp warm water to individual zones.

Technical Integration & Irish Compliance Engineering

Designing heating systems that align with NSAI, CE, Part L, and DEAP modeling requirements.

Understanding NSAI Standards and Heat Pump Optimization

In Ireland, heating design is modeled using the Dwelling Energy Assessment Procedure (DEAP) to verify compliance with Building Regulations Part L. To maximize efficiency under DEAP, heating systems should be split into distinct control zones. Our Multi-Zone wiring centers allow contractors to establish independent temperature programs for living and sleeping spaces, supporting energy compliance requirements.

When pairing hydronic loops with air-to-water heat pumps, managing cycle times is critical. Rapid cycling can reduce compressor life and degrade overall system efficiency. Our thermal actuators feature controlled opening and closing periods (typically 3–5 minutes). This prevents sudden hydraulic shifts, allowing heat pump variable-speed circulating pumps to adjust flow rates smoothly and maintain steady condensing temperatures.

CE & UKCA Certified Manufacturing Control

Compliance is the baseline of our production facility. All products destined for the Irish and wider European market carry full CE Certification. From electromagnetic compatibility (EMC) testing for room thermostats to high-pressure burst testing for brass manifolds and check valves, our quality control team checks every batch. This commitment to compliance helps engineers, contractors, and merchants specify Cokaren hardware with confidence.

Actuator Engineering Specifications

Operating Voltage 230V AC or 24V AC/DC (50/60Hz)
Thread Connection M30 x 1.5 mm (Standard EU Fitting)
Power Consumption 1.8W to 2.0W (Energy Efficient)
Stroke Depth 3.0 mm to 4.5 mm
Waterproof Rating IP54 (EN 60529 Compliant)
Opening/Closing Time Approx. 180 seconds (Slow Close)
Working Temp Limits 0°C to 60°C Ambient Range

Technology Roadmap: Next-Gen Hydronic Controls

Designing components that support next-generation building networks, smart grid integration, and remote management protocols.

Matter & Thread Standards

Our product team is integrating Matter-over-Thread hardware platforms into our smart thermostats. This will enable direct connection to popular smart home ecosystems without requiring dedicated proprietary gateways.

Target Deployment: Q4 2024

Dynamic Peak-Shaving

Working alongside utility providers, our next-generation wiring centers can receive peak electricity price warnings, temporarily shutting down UFH thermal valves during peak demand windows to reduce overall operating costs.

Target Deployment: Mid 2025

Proportional Control Actuators

Moving beyond basic ON/OFF thermal regulation, we are developing a line of 0-10V analog thermal actuators. These support fine-tuned, proportional flow adjustment to help maintain steady temperatures in hydronic loops.

Target Deployment: Q1 2025

Frequently Asked Questions (FAQ)

Common technical questions regarding our hydronic heating components, commissioning, and system compatibility.

Why are 230V Normally Closed (NC) actuators preferred for standard Irish domestic installations? +
Normally Closed (NC) actuators remain shut when no power is applied. This prevents uncontrolled heating loop circulation in the event of power cuts or system resets, helping safeguard the property. 230V options plug directly into standard wiring centers, removing the need for a separate transformer and simplifying the overall installation.
How do thermal actuators support air-to-water heat pump performance? +
Wax-element thermal actuators open and close slowly over a 3-5 minute window. This gradual action prevents rapid pressure spikes and flow changes in the hydronic loop, allowing modern heat pump circulation pumps to scale their speed smoothly and maintain stable system pressures.
Are the Cokaren brass manifolds compatible with third-party thermal actuators? +
Yes, our underfloor heating manifolds utilize the standard M30 x 1.5 mm mounting thread configuration. This design allows them to accept thermal actuators from most major European control brands, providing flexibility for retrofit projects.
What steps are taken to prevent scale build-up in domestic plumbing and heating loops? +
Our brass components are manufactured using high-durability, corrosion-resistant brass. Additionally, installing a system protection device like the Y9021 Domestic Water Filter helps collect metal scale, sand, and particulate matter before it can settle inside valve seats or actuator plungers.
Does the Cokaren multi-zone controller box handle boiler and pump relays? +
Yes, our CE-certified wiring centers feature built-in, volt-free boiler interlock contacts and dedicated pump control relays. When any thermostat calls for heat, the hub opens the corresponding thermal actuators, waits for them to activate, and then starts the system pump and heat source.

Partner with an Established HVAC Controls Manufacturer

Providing OEM/ODM solutions to distributors, contractors, and mechanical engineering groups throughout Ireland. Reach out today for pricing, technical sheets, or custom volume manufacturing queries.

Submit Request for Quote